Science Lab Supplies is a leading Ultra-pure water conductivity cell Manufacturer,and suppliers in India, Ultra-pure water conductivity cell Uruguay (Montevideo), Ultra-pure water conductivity cell Uzbekistan (Tashkent), Ultra-pure water conductivity cell Venezuela (Caracas), Ultra-pure water conductivity cell Vietnam (Hanoi), Ultra-pure water conductivity cell Yemen (Sana'a), Ultra-pure water conductivity cell Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Description : 
With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 µS/cm) e.g. boiler feed water or deionised water. 
Cable length 1.5 metres. 
Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range : 0.001µS/cm to 200µS/cm.

Specifications :
Measuring principle : 2 electrode measuring cells
Measuring range : 0.001 µS/cm ... 200 µS/cm
Cell constant : K = 0.1 cm - 1
Resolution : Depends on measuring range
Temperature sensor : Integrated NTC
Temperature measurement : -5 °C ... 80 °C
Maximum pressure : 2 bar
Electrical connection : Integrated cable with 8-pole plug
Shaft : Stainless-steel 1.4571
Connection head : POM
Electrodes : Stainless-steel 1.4571

   